<title><![CDATA[ANALISIS EKSERGI DALAM EVALUASI KINERJA SISTEM COMBINED HEAT AND POWER PTPN X PABRIK GULA PESANTREN BARU]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Ari Agustin</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[JURUSAN TEKNIK]]></placeTerm></place>
<publisher><![CDATA[PROGRAM STUDI TEKNIK ENERGI TERBARUKAN]]></publisher>
<dateIssued><![CDATA[2018]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[Publish]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[en]]></languageTerm>
<languageTerm type="text"><![CDATA[English]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[]]></form>
<extent><![CDATA[20cm]]></extent>
</physicalDescription>
<note>Exergy Analysis in Evaluation of Combined Heat and Power System
PTPN X PabrikGulaPesantrenBaru
BayuRudiyanto as chief counselor andMochammadNuruddin as
member counselor


Ari Agustin
Study Program ofRenewable Energy Engineering
Department of Engineering
PoliteknikNegeriJember
agustinoari@rocketmail.com


ABSTRACT


Since the beginning of operation, PG PesantrenBaru has been integrated with cogeneration system of bagasse-based which classified as CHP system. This research willevaluate CHP system in scope of thermodynamics with an exergy analysis method, so can be known number of distribution two energy forms of cogeneration and system performance. CHP system produces two energy forms simultaneously from one primary energy source, namely the form of mechanical energy (power) is 69,098.3 kW and heat is 2,662 kW. While the performance of CHP system tends not optimal. Performance of CHP system is affected by equilibrium between magnitude of exergy destruction and exergy efficiency of the system. More fundamentally, exergy analysis is able to interpret factors that cause irregularities of a system according to Second Law of Thermodynamics. Factors that cause a system's irregularities is described by irreversibility (inability to reverse). There are two types of irreversibility, namely internal irreversibility and external irreversibility. Exergy destruction refers to internal irreversibility and influenced by entropy flow of internal irreversibility that appears from process of heat transfer spontaneously. The heat transfer spontaneously allows exergy destruction to occur only in heat exchanger components or components that involve temperature differences in the process.


Keywords: sugar industry, CHP system, exergy, irreversibility, exergy destruction</note>
<subject authority=""><topic><![CDATA[TEKNIK ENERGI TERBARUKAN]]></topic></subject>
<classification><![CDATA[]]></classification><identifier type="isbn"><![CDATA[20181113]]></identifier><location>
<physicalLocation><![CDATA[E-Library POLIJE Sistem Elektronik Tesis Dan Disertasi]]></physicalLocation>
<shelfLocator><![CDATA[]]></shelfLocator>
</location>
<slims:digitals>
<slims:digital_item id="1289" url="" path="/22. LAPORAN LENGKAP.pdf" mimetype="application/pdf"><![CDATA[ANALISIS EKSERGI DALAM EVALUASI KINERJA SISTEM COMBINED HEAT AND POWER PTPN X PABRIK GULA PESANTREN BARU]]></slims:digital_item>
</slims:digitals><slims:image><![CDATA[0._COVER.jpg.jpg]]></slims:image>
<recordInfo>
<recordIdentifier><![CDATA[20982]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2018-11-13 15:00:53]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2018-11-13 15:00:53]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>