KINERJA POMPA HIDRAM DENGAN PENAMBAHAN JUMLAH KATUP LIMBAH PADA VARIASI HEAD OUTPUT SEBAGAI ALTERNATIF POMPA AIR TANPA LISTRIK
Kinerja Pompa Hidram dengan Penambahan Jumlah Katup Limbah Pada Variasi Head Output Sebagai Alternatif Pompa Air Tanpa Listrik
(Performance of Hydraulic Ram Pump with Addition of Waste Valves on Head Output Variations as an Alternative Water Pump without Electricity)
Mohammad Imam Hidayatullah
Program Studi Teknik Energi Terbarukan
Jurusan Teknik
ABSTRAK
Air merupakan kebutuhan penting bagi manusia. Namun pada daerah tertentu sulit untuk mendapatkannya terutama masyarakat yang bermukim di tempat tinggi yang sumber airnya ada di bawah. Dalam hal ini penggunaan pompa hidram dapat membantu masyarakat. Pompa hidram yang ada saat ini umumnya menggunakan satu katup limbah. Metode yang digunakan adalah eksperimen yaitu dengan menambah jumlah katup limbah dan menguji kinerjanya pada beberapa variasi head output. Pada penelitian ini juga membandingkan pompa hidram dan pompa air listrik untuk mengisi tandon ditinjau dari debit, lama waktu pengisian dan konsumsi energinya. Hasil penelitian didapat bahwa jumlah katup limbah memiliki pengaruh terhadap kinerja pompa hidram. Debit output tertinggi pompa hidram 1 katup limbah dan 2 katup limbah diseri pada head output 7 meter berturutturut adalah 1,949 dan 4,398 liter/menit. Terjadi penigkatan 125%. Tekanan tabung head 7 meter, pompa 1 katup limbah dan 2 katup diseri berturut turut 0,68 dan 0,75 bar. Terdapat peningkatan 10,3%. Efisiensi D’Aubuission tertinggi pompa hidram 1 katup limbah dan 2 katup limbah diseri adalah 31,84% dan 37,97% pada head 7 meter. Untuk pengisian tandon dengan head 4,3 meter, pompa hidram terbaik membutuhkan waktu 57,81 menit sedangkan pompa air listrik 12,3 menit. Konsumsi energi listrik pompa air sebesar 74,176 wh. Sedangkan pompa hidram tidak membutuhkan energi listrik dalam penerapannya.
Kata Kunci: Pompa Hidram, Air, Katup Limbah, Konsumsi Energiix
Kinerja Pompa Hidram dengan Penambahan Jumlah Katup Limbah Pada Variasi Head Output Sebagai Alternatif Pompa Air Tanpa Listrik
(Performance of Hydraulic Ram Pump with Addition of Waste Valves on Head Output Variations as an Alternative Water Pump without Electricity)
Mohammad Imam Hidayatullah
Renewable Energy Engineering Program Study
Engineering Department
ABSTRACT
Water is an important requirement for humans. However, in certain areas it is difficult to get it, especially people who live in high places where the water source is below. In this case the use of a hydraulic ram pump can help the community. Hydraulic ram pump currently use one waste valve. The method used is an experiment that is by increasing the number of waste valves and testing their performance on a number of output head variations. In this study also compared the hydraulic ram pump and electric water pump to fill the reservoir in terms of the discharge, the length of filling time and energy consumption. The results showed that the number of waste valves had an influence on the performance of the hydraulic ram pump. The highest output discharge of 1 waste valve and 2 waste valves in the 7 meter output head are 1.949 and 4.398 liters/minute, respectively. 125% increase occurs. 7 meter head tube pressure, 1 waste valve pump and 2 valves in series respectively 0.68 and 0.75 bar. There is a 10.3% increase. The highest D'Aubuission efficiency of 1 waste valve hydraulic ram pump and 2 waste valve valves is 31.84% and 37.97% in 7 meter head. To fill the tank with a 4.3 meter head, the best hydraulic ram pump takes 57.81 minutes while the electric water pump is 12.3 minutes. Electric pump water consumption is 74,176 wh. While the hydraulic ram pump does not need electricity in application.
Key words: Hydraulic Ram Pump, Water, Waste Valve, Energy Consumtion.
Detail Information
Bagian |
Informasi |
Pernyataan Tanggungjawab |
Mohammad Imam Hidayatullah |
Pengarang |
Mohammad Imam Hidayatullah - Personal Name (Pengarang) |
Edisi |
Publish |
No. Panggil |
|
Subyek |
TEKNIK ENERGI TERBARUKAN
|
Klasifikasi |
|
Judul Seri |
|
GMD |
Text |
Bahasa |
English |
Penerbit |
|
Tahun Terbit |
2018 |
Tempat Terbit |
|
Deskripsi Fisik |
20 Cm |
Info Detil Spesifik |
|
Citation
Mohammad Imam Hidayatullah. (2018).
KINERJA POMPA HIDRAM DENGAN PENAMBAHAN JUMLAH KATUP LIMBAH PADA VARIASI HEAD OUTPUT SEBAGAI ALTERNATIF POMPA AIR TANPA LISTRIK(Publish).:
Mohammad Imam Hidayatullah.
KINERJA POMPA HIDRAM DENGAN PENAMBAHAN JUMLAH KATUP LIMBAH PADA VARIASI HEAD OUTPUT SEBAGAI ALTERNATIF POMPA AIR TANPA LISTRIK(Publish).:,2018.Text
Mohammad Imam Hidayatullah.
KINERJA POMPA HIDRAM DENGAN PENAMBAHAN JUMLAH KATUP LIMBAH PADA VARIASI HEAD OUTPUT SEBAGAI ALTERNATIF POMPA AIR TANPA LISTRIK(Publish).:,2018.Text
Mohammad Imam Hidayatullah.
KINERJA POMPA HIDRAM DENGAN PENAMBAHAN JUMLAH KATUP LIMBAH PADA VARIASI HEAD OUTPUT SEBAGAI ALTERNATIF POMPA AIR TANPA LISTRIK(Publish).:,2018.Text